SCSI HDD 수리

1SU41010 RELIANCE ELECTRIC DRIVE 10HP 460V NEMA 1 SP500

skyu0021 2013. 1. 4. 14:36

 

SP500 Manual for the SP500 AC Controller
To Change Parameters
Press stop/reset key to stop the drive.
Press mode/enter key, Program LED should light.
Press up/down arrow key until desired function.
Press mode/enter button which display value within function.
Use up/down keys to change parameter content.
Press mode/enter button.
Press stop/reset button to exit programming mode.


To View and Clear Error Log
Press stop/reset key to stop the drive.
Press mode/enter button to enter program mode.
Use down arrow key until Err is displayed.
Press mode/enter keys to scroll through errors.
Press stop/reset key to clear faults.


Possible Faults
HU D–C high bus voltage condition
LU D–C low bus voltage condition
OL Electronic thermal overload
OH Controller high temperature
OC Overcurrent, short circuit protection
FL External function loss 

 

1SU41010 RELIANCE ELECTRIC

DRIVE 10HP 460V NEMA 1 SP500